The Structure Cable 500mcm Solitary Conductor Rwu90 RW90 Cable television Copper Rounded UL Building THHN 11kv 3 Center Xlpe Cable television LOW Voltage 600V will be the service perfect your building needs. The cable television is produced due to the brand widely known Cable television, which could be comprehended because of its own high-quality products.
This cable television consists of a conductor solitary a 500mcm deepness, that might be created coming from copper, making it a suitable option for durable requests. Its own UL building assists towards ensure that it fulfills the safety and safety demands being biggest in the market place.
The THHN 11kv 3 Center Xlpe Cable television is really a cable television flexible might be utilized for the quantity of requests. Its own created towards endure severe problems which are environmental like for instance severe problems, chemical moisture, substances. This will guarantee it is effectively fit for used in industrial setups which are industrial.
The cable television has type rounded which enables you towards place handle in. Furthermore functions a voltage reduced of 600V, making it risk-free towards utilize in reduced voltage requests. Possessing a duration of 500m, its own utilize suitable within building jobs.
The Structure Cable 500mcm Solitary Conductor Rwu90 RW90 Cable television Copper Rounded UL Building THHN 11kv 3 Center Xlpe Cable television LOW Voltage 600V was produced towards provide efficiency exceptional reliability. Its own building top quality assurances it may endure most likely the most difficult functioning problems.
This cable television is an outstanding choice whether you have to energy equipment, lighting or even devices. Its own voltage reduced rack up it suitable utilize within lots of requests. It could be utilized in business like for instance gas oil, mining, building, an entire a lot more.
Building Wire 500mcm Single Conductor Rwu90 RW90 Cable
Application
For use as general-purpose wiring for installation in conduit or other recognized raceway.
Standard
• c22.2
Construction
Conductors: Bare, soft annealed stranded copper
Insulation: XLPE
Specifications:
MM2 |
AWG/Kcmil |
Diameter of conductor |
Min. No of wire |
Insulation Thickness |
Jacket Thickness |
Diam. |
Approx. Wt. |
NEC |
|
- |
- |
- |
mm |
n |
mm |
mm |
mm |
Kg/km |
90oC Ampacity |
2.08 |
14 |
AWG |
1.85 |
7 |
0.38 |
0.1 |
2.8 |
25 |
25 |
3.31 |
12 |
AWG |
2.32 |
7 |
0.38 |
0.1 |
3.3 |
37 |
30 |
5.26 |
10 |
AWG |
2.95 |
7 |
0.51 |
0.1 |
4.2 |
59 |
40 |
8.37 |
8 |
AWG |
3.71 |
7 |
0.76 |
0.13 |
5.5 |
96 |
55 |
13.3 |
6 |
AWG |
4.67 |
7 |
0.76 |
0.13 |
6.5 |
145 |
75 |
21.2 |
4 |
AWG |
5.89 |
7 |
1.02 |
0.15 |
8.2 |
232 |
95 |
33.6 |
2 |
AWG |
7.42 |
7 |
1.02 |
0.15 |
9.8 |
352 |
130 |
42.4 |
1 |
AWG |
8.43 |
19 |
1.27 |
0.18 |
11.3 |
452 |
145 |
53.5 |
1/0 |
AWG |
9.45 |
19 |
1.27 |
0.18 |
12.4 |
559 |
170 |
67.4 |
2/0 |
AWG |
10.62 |
19 |
1.27 |
0.18 |
13.5 |
692 |
195 |
85 |
3/0 |
AWG |
11.94 |
19 |
1.27 |
0.18 |
14.8 |
860 |
225 |
107 |
4/0 |
AWG |
13.41 |
19 |
1.27 |
0.18 |
16.3 |
1068 |
260 |
127 |
250 |
Kcmil |
14.60 |
37 |
1.52 |
0.2 |
18.0 |
1279 |
290 |
152 |
300 |
Kcmil |
16.00 |
37 |
1.52 |
0.2 |
19.4 |
1516 |
320 |
177 |
350 |
Kcmil |
17.30 |
37 |
1.52 |
0.2 |
20.7 |
1751 |
350 |
203 |
400 |
Kcmil |
18.49 |
37 |
1.52 |
0.2 |
21.9 |
1995 |
380 |
253 |
500 |
Kcmil |
20.65 |
37 |
1.52 |
0.2 |
24.1 |
2463 |
430 |